Description

The observation of volcanic sulphur dioxide (SO$_2$) emissions enables to monitor volcanic activity by quantifying degassing fluxes of volcanic plumes. Recently applied imaging techniques based on non-dispersive optical remote sensing (SO$_2$ cameras) reach a high spatial and temporal resolution. However, due to the limited spectral information, this technique lacks sensitivity, and selectivity and hence it is limited to high volcanic trace gas emissions and favourable measurement conditions.
We present the first measurements of volcanic SO$_2$ emissions with an imaging Fabry-Perot interferometer correlation spectroscopy (IFPICS) prototype in the UV spectral range.
The principle of IFPICS is to employ a Fabry Perot interferometer (FPI), replacing interference filters as wavelength selective elements. The FPI’s periodic transmission profile correlates with the periodic structure of the SO$_2$ spectral absorbance, significantly increasing the spectral information for its detection. This reduces cross sensitivities (e.g. ozone interference, aerosols, clouds), allowing to use IFPICS also for weaker volcanic SO$_2$ emitters, increasing the range of possible atmospheric measurement conditions, and applying the technique to other trace gas species e.g. bromine monoxide or chlorine dioxide. Furthermore, IFPICS does not require calibration with gas cells since calibration with literature cross section is feasible.
The volcanic SO$_2$ column density distributions obtained at Mt. Etna, Sicily were recorded with 0.2 Hz and 400 x 400 pixels reaching a sensitivity of $1\times10^{-19}$ cm$^2$ molec$^{-1}$ at a detection limit of $3\times10^{17}$ molec cm$^{-2}$ s$^{-1/2}$, which is comparable to existing filter-based SO$_2$ cameras.

Authors

Mr Christopher Fuchs (Institute of Environmental Physics, Heidelberg University, Germany) Mr Jonas Kuhn (Institute of Environmental Physics, Heidelberg University, Germany) Dr Nicole Bobrowski (Institute of Environmental Physics, Heidelberg University, Germany) Prof. Ulrich Platt (Institute of Environmental Physics, Heidelberg University, Germany)