Antibody purification is a critical step in manufacturing and analytical workflows, yet conventional Protein A affinity chromatography often requires acidic elution, risking structural alterations and necessitating additional processing for mass spectrometry (MS). We present a Protein A-functionalized regenerated cellulose membrane adsorber with conductive gold-coated layers, enabling voltage-triggered elution—termed Digital Membrane Chromatography (DMC). Using Trastuzumab as a model, DMC achieved efficient antibody capture and mild, MS-compatible elution without desalting or buffer exchange. This approach preserves structural integrity, supports analysis from complex matrices, and reduces processing time compared to conventional methods.